FSC-6 Specifications and Features
|
|
Safety Features
-
Full dual channel operation
-
Positive operation state indicators
-
Force guided relay
-
Redundant critical control components
-
Configuration for ANSI B11.19 guidelines
-
Controlled access for installation, operation
-
NEMA 12 and 13 enclosure
-
Factory configured and inspected
Additional Protection Features (Optional)
-
Illuminated reset button
-
Additional light tower indicators
-
Key operated mandatory reset
-
Padlock kit for lock-out
Enclosure
Standard - NEMA-12 -
8" x 8" x 6"
Optional - 4X
Enclosure Fastening Technique
Standard - Front panel screw - tamper resistant Optional - Key-lock, mechanical
lockout
|
|
FSC Series - Safety Control
|
Model |
Sizes |
Description |
|
FSC-6-R |
1.75" x 3" x 4.75" |
Din Rail Relay |
|
FSC-6-1Z |
8" x 8" x 4" |
1 Zone |
|
FSC-6-2Z |
10" x 8" x 6" |
2 Zone |
|
FSC-6-3Z |
14" x 8" x 6" |
3 Zone |
|
FSC-6-4Z |
14" x 8" x 6" |
4 Zone |
|
Special control configurations available. |
Machine Controls Outputs
Standard - 2 channel safe circuit
Contacts - 2 N.O. safety contacts
Contact type - Forced contact
Contact material - Ag-Alloy; Gold-plated
Switching voltage - 230/230 V AC/DC
Maximum continuous current per contact - 6 amps
Mechanical lifetime - 10 x 106 switching cycles
Recovery time (without RESET monitoring) - 8000 mSec
Working range ambient temperature: -25 to +55 °C
Internal Configuration
DIN 35mm rail design
Cage-Clamp wire design, touch safe
Isolated power, Switchmat, and machine control inputs
|
Power
Standard - 120 VAC 60 HZ
Optional - 24 VDC
Rated voltage - 120 VAC
Rated consumption at 50 Hz - 2.5 watts
Rated frequency - 50 to 60 Hz
AC: Short-circuit proof transformer |
|
Presence Sensor Inputs
Standard - Single safety mat
Optional - Multiple zone inputs
Light screen
Gate switch
Limit switch
Positive sensor identification
|
Front Panel Indicators
Standard -
Normal: GREEN
Halt: RED |
|
Front Panel Controls
Optional -
Manual RESET
Key operated RESET
|
Risk Assessment
The level of safety protection required for a given application is based on the
risk associated with that application. The risk associated with an operation is
based on a number of factors that must be taken together and evaluated in total
to establish the risk level for any equipment or operation.
|
|
Partial Listing of Applicable Safety Standards
|
ANSI B11.19-1990 Machine Tools - Safeguarding when referenced
by other B11 machine tool safety standards - performance criteria for the design,
construction, care, and operation
ANSI/RIA R15.06-1992 - for Industrial Robots and Robot Systems - Safety Requirements
|
|
ANSI Z244.1-1982 Personnel protection - Lockout/tagout
of energy sources - Minimum safety requirements
ANSI/ASME B15.1 - 1984 Safety standard for mechanical power transmission
apparatus
ANSI/NFPA 79-1991 Electrical standard for industrial machinery
|